Location:
Eye Massager Complete Machine Standards Guide: Current vs. Superseded Standards, Key Technical Indicators and Compliance Path

Eye Massager Complete Machine Standards Guide: Current vs. Superseded Standards, Key Technical Indicators and Compliance Path

Two safety national standards, one dedicated association standard and four supporting standards, int

2026-11-17 12:00
QR code
1
<a href="https://www.honghebusiness.com/h-pr-j-3_21.html?pcp=21" target="_blank" textvalue="Eye Massager" class="ue_anchorStyleText">Eye Massager</a> Complete Machine Standards Guide: Current vs. Superseded Standards, Key Indicators and Compliance Path
Source: National Standards Information Public Service Platform (std.samr.gov.cn) — click to verify standards

Eye Massager Complete Machine Standards Guide

Current vs. superseded standards, key technical indicators and compliance implementation path · Version V1.1 · Compiled 17 November 2026

Title

Eye Massager Complete Machine Standards Guide: Current vs. Superseded Standards, Key Technical Indicators and Compliance Path

SubTitle

Two safety national standards, one dedicated association standard and four supporting standards, integrated across product, quality, regulatory and supply chain functions

KeyWords

eye massager,GB/T 4706.1—2024,GB/T 4706.10—2024,T/CHEAA 0031—2024,GB 4343.1—2024,GB 31241—2022,standard transition,re-testing,certification,test report,compliance implementation

Description

A standards guide for product, quality, regulatory and supplier-management roles in the eye-massager category.
It sets out the current status and effective dates of GB/T 4706.1—2024, GB/T 4706.10—2024, GB 4343.1—2024, GB 31241—2022 and T/CHEAA 0031—2024.
It provides an old-versus-new comparison table, transition milestones, guidance on legacy reports, CCC applicability and a practical testing roadmap.
It can be used directly for nameplate verification, report registers and e-commerce compliance review.

Abstract

From 1 August 2026, GB/T 4706.1—2024 and GB/T 4706.10—2024 take effect, fully replacing the 2005 and 2008 editions respectively.
GB 4343.1—2024 takes effect on 1 June 2026, replacing the 2018 edition.
GB 31241—2022 has been in force since 1 January 2024.
The current basis for the complete machine can be summarised as "two safety national standards, one dedicated association standard and four supporting standards".
This document gives the standard list, old-versus-new comparison, performance indicators, milestones and certification routes, and flags three boundary risks: medical devices, radio transmission and electrical pulse principles.

Content Mind Map

Eye Massager Complete Machine Standards
1. Current standards
General safety: GB/T 4706.1—2024 (effective 2026-08-01)Particular safety: GB/T 4706.10—2024 (effective 2026-08-01)Dedicated product standard: T/CHEAA 0031—2024 (effective 2024-04-02)EMC emission: GB 4343.1—2024 (effective 2026-06-01)EMC immunity: GB/T 4343.2—2020 (2026 edition published, pending)Harmonic current: GB 17625.1—2022 (effective 2024-07-01)Lithium battery: GB 31241—2022 (effective 2024-01-01)  
2. Old-versus-new comparison
GB 4706.1—2005 → GB/T 4706.1—2024: status changed to recommended, identical adoption of IEC 60335-1:2016GB 4706.10—2008 → GB/T 4706.10—2024: identical adoption of IEC 60335-2-32:2019GB 4343.1—2018 → GB 4343.1—2024: transition window 2025-04-20 to 2026-05-31GB 17625.1—2012 → GB 17625.1—2022GB 31241—2014 → GB 31241—2022T/CHEAA 0031—2024 is a new standard with no predecessor  
3. Association standard requirements
Safety: complies with both safety national standards and GB 31241—2022Pressure: airbag pressure not exceeding 78 kPa during operationHeat: skin-contact surface temperature not exceeding 43 °CNoise: sound power level not exceeding 55 dB(A)Life: unit ≥250 h, buttons ≥10,000 cyclesHygiene: antibacterial rate ≥90%, anti-mold grade ≥1, color fastness ≥grade 4  
4. Transition and legacy reports
2024-01-01 battery reports issued to the 2022 edition2024-07-01 harmonic current tested to the new edition2026-06-01 legacy EMC reports become invalid2026-08-01 legacy safety reports become invalidBuild a report register by standard version; any version change triggers re-testing  
5. Certification and market access
Eye massagers generally do not require CCC certificationObtain one complete-machine report covering safety, EMC, battery and hazardous substancesRed line 1: therapeutic claims require a medical-device registration routeRed line 2: wireless modules require type approvalRed line 3: electrical pulse principles follow a different standards route  
6. Testing and internal rollout
Labelling: remove old standard numbers and use current editions onlyReports: where differences are unclear, run the full test suiteDesign: pre-test heat plus charging, and 15-minute continuous operationSupply chain: batteries, heating film, pumps and masks transition in step  

1. About This Document

1.1 Purpose and scope

This document defines the current basis for standards compliance, factory inspection, third-party testing and platform compliance for eye massagers used in households and similar environments.
It can be cited directly by product definition, quality acceptance, supplier management and e-commerce onboarding teams.
It applies to complete machines that act on the eye area through airbag compression, mechanical pressing or heat compress.
This includes models powered by built-in lithium batteries, models powered by external adapters, and models with auxiliary functions such as Bluetooth music or voice prompts.
It does not apply to medical-use products or shared commercial products, nor to eye massagers based on electrical pulse principles (EMS, TENS).
The standards route for those products differs; see Section 6.3.

1.2 Data currency and sources

Standard status in this document was verified as of 17 November 2026.
The sources are the standard status and effective dates published on the National Standards Information Public Service Platform of the Standardization Administration of China, the text of T/CHEAA 0031—2024 issued by the China Household Electrical Appliances Association, and the mandatory product certification implementation rules of the CNCA.
Where standard status, effective dates or supersession relationships change, the official platform prevails.

2. Current Standards for the Complete Machine

2.1 Overall conclusion

From 1 August 2026, GB/T 4706.1—2024 and GB/T 4706.10—2024 take effect.
They fully replace GB 4706.1—2005 and GB 4706.10—2008 respectively.
GB 4343.1—2024 takes effect on 1 June 2026, replacing GB 4343.1—2018.
This means the "standards" entry on nameplates, in instruction manuals and in test reports must be updated to the new numbers.
Continuing to mark the 2005 or 2008 editions will be judged as labelling inconsistent with current standards.

The current basis for the complete machine can be summarised as two safety national standards, one dedicated association standard and four supporting standards.
The safety standards are GB/T 4706.1—2024 and GB/T 4706.10—2024.
The dedicated performance and hygiene standard is T/CHEAA 0031—2024.
The supporting standards are GB 4343.1—2024, GB/T 4343.2—2020, GB 17625.1—2022 and GB 31241—2022.

Note that GB/T 4706.1—2024 and GB/T 4706.10—2024 are recommended national standards.
However, both are cited in local massage-appliance quality supervision sampling rules and in e-commerce platform quality rules, so they are enforced as mandatory in practice.
The "GB/T" prefix must not be taken as a reason to lower requirements.

2.2 Standard list

Table 1 — Current standards for the eye massager complete machine

No.CategoryStandard No.TitleEffective dateStatus
1Safety (general)GB/T 4706.1—2024Household and similar electrical appliances — Safety — Part 1: General requirements2026-08-01Recommended
2Safety (particular)GB/T 4706.10—2024Household and similar electrical appliances — Safety — Part 10: Particular requirements for massage appliances2026-08-01Recommended
3Dedicated productT/CHEAA 0031—2024Household and similar eye massagers2024-04-02Association standard
4EMC emissionGB 4343.1—2024Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 1: Emission2026-06-01Mandatory
5EMC immunityGB/T 4343.2—2020Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity2021-07-01Recommended
6Harmonic currentGB 17625.1—2022Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase)2024-07-01Mandatory
7Lithium batteryGB 31241—2022Safety technical specification for lithium-ion cells and batteries used in portable electronic products2024-01-01Mandatory

Source: National Standards Information Public Service Platform (std.samr.gov.cn).
Status verified as of 17 November 2026.
GB/T 4343.2—2026 has been published and will fully replace the 2020 edition; it should be adopted once it takes effect.

2.3 Superseded standards

The safety and supporting standards relevant to eye massagers were mostly issued between 2005 and 2018, and all previous editions have now been withdrawn.
There are two reasons to keep a list of the old editions.
First, to check whether nameplates, manuals, tender documents and purchase contracts still cite withdrawn standard numbers.
Second, to define the comparison baseline for transition re-testing and clarify which items must be repeated.

Previously there was no dedicated product standard for eye massagers.
Manufacturers generally wrote their own enterprise standards, or referred to GB 4706.10 and QB/T 4412 "Hand-held electric massagers".
T/CHEAA 0031—2024 is a newly created standard rather than a replacement of an older one, so it is not listed in the table below.

Table 2 — Withdrawn or superseded standards

No.Standard No.TitleStatusWithdrawal dateReplaced by
1GB 4706.1—2005Household and similar electrical appliances — Safety — Part 1: General requirementsMandatory2026-08-01GB/T 4706.1—2024
2GB 4706.10—2008Household and similar electrical appliances — Safety — Part 10: Particular requirements for massage appliancesMandatory2026-08-01GB/T 4706.10—2024
3GB 4343.1—2018Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 1: EmissionMandatory2026-06-01GB 4343.1—2024
4GB 17625.1—2012Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase)Mandatory2024-07-01GB 17625.1—2022
5GB 31241—2014Safety technical specification for lithium-ion cells and batteries used in portable electronic productsMandatory2024-01-01GB 31241—2022
6GB/T 4343.2—2020Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 2: ImmunityRecommendedDate GB/T 4343.2—2026 takes effectGB/T 4343.2—2026

Source: standard status and supersession relationships on the National Standards Information Public Service Platform.
"Withdrawal date" is the date on which the superseded standard ceases to apply.

2.4 Nameplate and manual marking

It is recommended to mark the "Standards" entry on the nameplate in full as follows.
Standards: GB/T 4706.1—2024, GB/T 4706.10—2024, T/CHEAA 0031—2024.
Models with built-in lithium batteries should also mark GB 31241—2022.

Chapter 7 of GB/T 4706.1—2024 requires appliances to state the manufacturer or responsible party name, model or serial number, rated voltage, rated input power or current and other parameters.
Marking the standards is voluntary, but e-commerce platform review, tender procurement and quality supervision sampling commonly require it, so it is advisable to list it in full.
Products with Bluetooth or other wireless modules should also state the module model and the radio transmission equipment type approval code in the manual or on a separate information page.

3. Old-versus-New Comparison

3.1 Summary table

The table below compares old standard, new standard, switch-over date and main changes.
It can be used directly for transition reviews, report registers and supplier communication.
The "main changes" column lists only verifiable facts and official interpretations.
Detailed clause differences should still be compared line by line against the standard texts; this table alone should not be used to decide whether a specific test must be repeated.

Table 3 — Old-versus-new comparison for eye massagers

CategoryOld standard (withdrawn)New standard (current)Switch-over dateMain changes and impact
Safety (general)GB 4706.1—2005GB/T 4706.1—20242026-08-01Status changed from mandatory GB to recommended GB/T.
Identical adoption of IEC 60335-1:2016.
Scope, temperature-rise limits and material flame-retardancy requirements are raised; legacy report data cannot be reused.
Safety (particular)GB 4706.10—2008GB/T 4706.10—20242026-08-01Same status change.
Identical adoption of IEC 60335-2-32:2019, aligned with the current international edition.
Classification, test conditions and pass criteria for massage appliances are updated.
EMC emissionGB 4343.1—2018GB 4343.1—20242026-06-01From 2025-04-20 to 2026-05-31 either edition may be chosen.
From 2026-06-01 only new-edition certificates are issued.
Emission limits and measurement methods follow the new edition.
EMC immunityGB/T 4343.2—2020GB/T 4343.2—2026Date the 2026 edition takes effectModified adoption of CISPR 14-2:2020.
The 2020 edition remains valid until the new edition takes effect, after which immunity is assessed to the new edition.
Harmonic currentGB 17625.1—2012GB 17625.1—20222024-07-01Limits and test conditions follow the new edition.
CCC certification and quality supervision sampling switch over in step.
Lithium batteryGB 31241—2014GB 31241—20222024-01-01Covers electrical safety, mechanical safety, environmental testing and protection circuits.
Battery reports must be issued to the 2022 edition.
Dedicated productNo dedicated standard (enterprise standards or reference to QB/T 4412)T/CHEAA 0031—20242024-04-02Establishes complete-machine indicators for airbag pressure, heat temperature, noise and life for the first time.
A new standard with no predecessor.
Hazardous substancesGB/T 26572—2011Remains valid, no replacement—Not revised in this round; assessed together with RoHS compliance.
Textile safetyGB 18401—2010Remains valid, no replacement—Eye masks, straps and other skin-contact parts are assessed as Category B.

Sources: standard status and supersession relationships on the National Standards Information Public Service Platform; CNCA and China Quality Certification Centre transition notices; July 2026 standard interpretation by the Beijing Municipal Administration for Market Regulation.

3.2 Main changes in the two safety standards

The revision of the safety standards involves two layers of change.
One is the status of the standard and the other is its technical content; they mean different things for manufacturers.

On status: GB 4706.1—2005 and GB 4706.10—2008 were mandatory national standards.
The new editions are recommended national standards, numbered GB/T 4706.1—2024 and GB/T 4706.10—2024.
The status change does not mean requirements are relaxed.
Both standards are cited in local massage-appliance quality supervision sampling rules and e-commerce platform quality rules, so sampling and platform review still follow the new editions.

On technical content: according to the standard interpretation published by the Beijing Municipal Administration for Market Regulation in July 2026, the new editions raise requirements in scope, temperature-rise limits, material flame-retardancy testing and other dimensions.
Three points affect eye massagers most directly.
The boundary conditions and limits of the temperature-rise test.
The flame-retardancy class of non-metallic materials such as housings and eye masks.
The judgement criteria for construction and marking checks.
Temperature-rise and flame-retardancy data in legacy reports cannot be cited directly and must be re-tested to the new editions.

On international alignment: the two new standards identically adopt IEC 60335-1:2016 and IEC 60335-2-32:2019 respectively.
Models that already hold CB reports or CE-LVD reports can use them for technical comparison to reduce duplicate testing.
However, identical adoption does not mean reports can be converted directly; sales in China still require reports issued by an accredited body.

3.3 Pace of EMC standard transitions

GB 4343.1—2024 replaces GB 4343.1—2018 and takes effect on 1 June 2026.
The transition arrangement published by the China Quality Certification Centre is as follows: from 20 April 2025 to 31 May 2026, manufacturers may choose to certify to either the new or the old edition.
From 1 June 2026, certification must follow the new edition and new-edition certificates are issued; old-edition certificates are no longer issued.
Although eye massagers are not in the mandatory product certification catalogue, EMC reports and platform sampling also follow the new edition.

On immunity: GB/T 4343.2—2020 is currently still in force.
GB/T 4343.2—2026 has been published and will fully replace the 2020 edition, with modified adoption of CISPR 14-2:2020, and must be adopted once it takes effect.
T/CHEAA 0031—2024 selects only electrostatic discharge, which is the minimum requirement of a product standard.
Other immunity items cannot be considered exempt on that basis.

On harmonic current: GB 17625.1—2022 took effect on 1 July 2024, replacing the 2012 edition.
Models powered by an external adapter, or operating while charging, should be tested to the new edition.

3.4 Battery and supporting standards

Battery is the earliest item to take effect in this transition round.
GB 31241—2022 took effect on 1 January 2024, replacing GB 31241—2014, and covers electrical safety, mechanical safety, environmental testing and protection circuits.
Built-in batteries and charging-case batteries in eye massagers are assessed to this standard, and reports must be issued to the 2022 edition.
Models holding only 2014-edition reports should be re-tested as soon as possible.

Hazardous substances and textile safety were not revised in this round.
GB/T 26572—2011 and GB 18401—2010 remain valid, covering RoHS limits and direct skin-contact (Category B) requirements respectively.
No new certification is needed at transition, but the edition numbers cited in reports and declarations should match the current editions to avoid referencing withdrawn versions.

3.5 Impact and response sequence

The practical impact of the transition centres on four areas: labelling, reports, design and the supply chain.
The recommended sequence is as follows.

  • Labelling: remove old standard numbers from nameplates, packaging, manuals and product detail pages of all SKUs on sale, and replace them with the current numbers in Table 1.
  • Reports: safety, EMC and battery reports issued to old editions become invalid after the switch-over dates.
    Where differences are unclear, full re-testing is safer than testing selected items.
  • Design: temperature rise and flame retardancy are high-risk items.
    Run an internal pre-test before sending samples, focusing on heat plus charging simultaneously and 15 minutes of continuous operation.
  • Supply chain: battery, heating film, air pump and mask suppliers should provide reports or declarations of conformity to the new editions in step.

4. Technical Requirements of the Dedicated Product Standard

4.1 Positioning and scope

T/CHEAA 0031—2024 was proposed by Shenzhen Breo Technology Co., Ltd. and is administered by the China Household Electrical Appliances Association.
It was published and took effect on 2 April 2024 and is the only dedicated complete-machine standard for this category.
The national standards system addresses the "safety floor" and does not specify performance such as airbag pressure, heat temperature, noise or life.
The association standard fills that gap and is the technical basis most often cited in platform quality checks, procurement acceptance and consumer complaint handling.

The standard applies to eye massagers used in households and similar places.
It explicitly does not apply to medical uses, commercial uses or eye massagers based on electrical pulse principles.

4.2 Safety requirements

  • The appliance shall comply with GB/T 4706.1—2024 and GB/T 4706.10—2024.
  • Lithium-ion cells and batteries used shall comply with GB 31241—2022.
  • The appliance shall not start or operate during charging, to avoid overheating from the combination of charging heat and heat compress.
  • Airbag pressure during operation shall not exceed 78 kPa, preventing pressure on the eyeball or discomfort around the eyes.

4.3 EMC requirements

Under continuous no-load operation, continuous disturbance limits and discontinuous disturbance limits shall comply with GB 4343.1—2024.

Immunity is assessed against the electrostatic discharge requirement of GB/T 4343.2.
The association standard selects only ESD, which does not exempt the complete machine from other immunity items.
For EU export or customer requirements, the full immunity suite should be tested.

4.4 Hygiene and safety requirements

  • Components claimed as antibacterial shall have an antibacterial rate of not less than 90%.
  • Components claimed as anti-mold shall have an anti-mold grade of not lower than grade 1.
  • Antibacterial and anti-mold performance are assessed to GB 21551.2; the objects assessed are usually textile parts and parts contacting the body during operation.
  • Restricted hazardous substances and their content shall meet the limits of GB/T 26572, and the labelling obligations of the administrative measures on the restriction of hazardous substances in electrical and electronic products shall be fulfilled.
  • Perspiration color fastness of textile parts shall be not lower than grade 4.
    Fabrics in direct contact with the body shall also meet the direct skin-contact (Category B) requirements of GB 18401.
  • Coated parts in direct contact with the body shall not show corrosion, discoloration, blistering, cracking or coating detachment after perspiration resistance testing.

4.5 Performance indicators

Table 4 — Key performance indicators in T/CHEAA 0031—2024

ItemRequirementKey test conditions
Massage timerWith a full charge, the time from power-on to automatic shutdown shall match the instruction manual and shall not exceed 15 min, with a timing error not exceeding ±2%Timed from start to automatic shutdown
Automatic shutdownThe appliance shall shut down automatically when the massage time is reachedAssessed together with the massage timer
Heat temperatureShall match the rated specification in the manual, and the surface temperature of body-contact parts shall not exceed 43 °CAmbient 23±2 °C, without significant airflow or heat radiation
Operating noiseSound power level not exceeding 55 dB(A-weighted), excluding music playbackFull charge, no load, all functions enabled
Low-battery alertA low-battery alert shall be provided, by sound, light or vibrationObserved at the low-battery state
Operating lifeNot less than 250 h; the appliance shall still operate normally after the life testContinuous or cyclic operation under specified conditions
Button lifeMechanical buttons not less than 10,000 cycles; normal operation after the testCyclic pressing at normal use frequency
Charging port lifeNot less than 1,000 cycles; good contact and normal charging after the testStandard insertion/removal cycles
Drop (bare unit)The appliance shall operate normally after the dropRelevant methods of GB/T 2423.7
Drop (packaged)No abnormality in appearance, structure or functionDrop with full packaging
Appearance and coatingNo scratches, scuffs or cracks on the surface.
Coating adhesion not lower than grade 2 of GB/T 9286
40 W fluorescent light, 45° angle, 30 cm viewing distance

Source: T/CHEAA 0031—2024 "Household and similar eye massagers", clauses 4.3 and 4.7 and Chapter 5 test methods.

4.6 Inspection rules

The standard divides inspection into factory inspection and type testing.
Factory inspection uses GB/T 2828.1 sampling and covers appearance, general function, marking and other items that can be judged quickly.
Type testing covers all requirements of Chapter 4 and is performed at product type approval, on major changes to structure or key components, on resumption of production after a stoppage, and during periodic sampling.
In-house inspection plans should correspond item by item to the association standard; factory inspection cannot replace type testing.

5. Transition Arrangements and Disposition of Legacy Reports

5.1 Key milestones

The withdrawal of the old editions does not happen on a single day.
Managing reports and labelling against the milestones below avoids the mismatch of "the new standard is in force but the report is still the old edition".

Table 5 — Old-to-new switch-over milestones

DateEventWhat manufacturers must do
2024-01-01GB 31241—2022 takes effectBattery reports issued to the 2022 edition; 2014-edition reports cease to be used
2024-04-02T/CHEAA 0031—2024 takes effectBenchmark complete-machine performance and hygiene indicators against it; usable as a higher-level reference for enterprise standards
2024-07-01GB 17625.1—2022 takes effectHarmonic current tested to the new edition
2025-04-20 to 2026-05-31GB 4343.1 transition windowEither edition may be chosen; testing directly to the new edition avoids a second transition
2026-06-01GB 4343.1—2024 becomes mandatoryOnly new-edition certificates are issued; legacy EMC reports become invalid
2026-08-01GB/T 4706.1 and GB/T 4706.10—2024 take effectOld safety editions are withdrawn; safety reports must be re-tested
Date GB/T 4343.2—2026 takes effectImmunity standard transitionAccording to the national standard announcement; assessed to the new edition thereafter

Note: the dates above are standard effective dates or policy deadlines; the national standard announcement and certification body notices prevail.

5.2 Suggested disposition of existing reports

Building a report register by standard version, with re-testing triggered by any version change, is more reliable than replacing reports on a fixed cycle.
For this product specifically, the suggestions are as follows.

  • Safety reports issued only to GB 4706.1—2005 and GB 4706.10—2008 can no longer serve as evidence of compliance with current standards after 1 August 2026 and should be re-tested to the new editions.
    Where differences are unclear, full re-testing is recommended.
  • EMC reports issued to GB 4343.1—2018 must be re-tested to the new edition after 1 June 2026.
  • Battery reports should be issued to GB 31241—2022.
    Those still on the 2014 edition must be redone.
  • Samples submitted during the transition should have the applicable standard edition year clearly stated in the report, avoiding the mismatch of "a valid report based on a withdrawn standard".

6. Certification and Market Access

6.1 CCC applicability

The current "Implementation Rules for Mandatory Product Certification — Household and Similar Electrical Appliances" (CNCA-C07-01:2024) covers household refrigerators, electric fans, air conditioners, household electric washing machines, electric water heaters, room heaters, vacuum cleaners, skin and hair care appliances, electric irons, induction cookers, electric ovens, electric food processing appliances, microwave ovens and others; massage appliances are not included.
Eye massagers therefore generally do not require CCC certification.

But "no CCC" does not mean "no standard constraints".
Product quality supervision sampling, platform onboarding review and tender qualification checks all follow the standards in Chapter 2, and the absence of a conformity report is itself a compliance risk.

6.2 Test report requirements

It is recommended to obtain in one go a complete-machine report covering safety, EMC, battery and hazardous substances.
It should be issued by a body holding CMA and CNAS accreditation, and the report should show the full standard numbers with edition years.
Platforms generally require recent reports from accredited bodies; the specific validity period and items depend on each platform's onboarding rules.
Derived models of the same type (appearance or colour changes only) can be listed in a report change page.
Changes to structure, key components or safety parameters require re-submission.

6.3 Three boundary red lines

Table 6 — Boundary compliance risks for eye massagers

Risk typeTriggerCorrect handling
Medical deviceClaims of treating myopia, dry eye, cataract or restoring vision, or design based on medical-device principlesFollow the medical-device registration or filing route; household-appliance testing alone is insufficient
Radio transmissionBuilt-in Bluetooth, Wi-Fi or other wireless modules without radio transmission equipment type approvalObtain type approval and state the module model and approval code in the manual or on an information page
Electrical pulseEMS, TENS or other electrical pulse methods applied around the eyesThe standards route differs; assess against the applicable standards and regulations rather than this list

7. Testing Submission and Internal Rollout

7.1 Preparing for testing

  • Confirm that the submitted model matches the production version and that the key-component list is complete.
  • State clearly which standard edition year is being applied for; avoid mixing editions.
  • Prepare the instruction manual, nameplate artwork, key-component list and circuit diagrams.
  • For models with built-in lithium batteries, prepare battery reports to the 2022 edition.
  • For adapter-powered models or models operating while charging, prepare harmonic current testing.

7.2 Internal rollout actions

  • Product: verify airbag pressure, heat temperature ceiling and timer logic against the hard indicators in the association standard.
  • Quality: sample factory inspection to GB/T 2828.1, with items corresponding one-to-one to the association standard.
  • Regulatory: maintain a report register by standard version; any version change triggers re-testing.
  • Supplier management: battery, heating film, air pump and mask suppliers transition in step and provide declarations of conformity.
  • E-commerce and marketing: remove old standard numbers from detail pages, packaging and manuals across the board.

7.3 Scheduling

It is recommended to start testing at least 90 days before the transition effective dates.
Full safety re-testing and EMC re-testing can be scheduled in parallel.
Battery and key-component reports should be confirmed first, so that supply-chain documentation delays do not hold up complete-machine certification.

Overall Analysis

The core value of this document is that it translates "standard numbers" back into "executable compliance actions".
The eye-massager category long lacked a dedicated national standard: safety relied on general household-appliance standards, and performance relied on each manufacturer's own enterprise standard.
The introduction of T/CHEAA 0031—2024 writes airbag pressure, heat temperature, noise, life and hygiene — indicators that directly affect user experience — into a formal text for the first time.
This shifts competition from "can it pass safety" to "can performance indicators be quantitatively verified".

Looking at the transition schedule, this round of adjustment does not complete on a single day.
The battery standard came first in January 2024, harmonic current followed in July 2024, EMC emission switches in June 2026, the two safety national standards land in August 2026, and the immunity standard is still pending.
The risk most easily overlooked in such staggered transitions is a mixed state where some reports have been updated and others have not.
Manufacturers who replace reports on a fixed cycle can easily end up with a report that no longer matches the standard at some point in time.

Another point worth noting is the change in standard status.
The two safety national standards move from mandatory GB to recommended GB/T, which looks like a relaxation on the surface.
But supervision sampling rules and e-commerce platform quality rules still follow the new editions, so the practical binding force has not decreased.
The lesson for manufacturers is that compliance judgement cannot rely on the prefix alone; it depends on the referencing context.

In summary, the rollout priorities in this document can be reduced to three sentences.
Update the nameplate first, then fill in the reports.
Where differences are unclear, run the full suite.
Transition the supply chain in step.
Put these three tasks into the project plan against the milestones and the transition risk is largely under control.

Core Problem, Solution, Execution and Acceptance Model

Core problem

Staggered old-to-new transitions create mismatches between nameplate labelling, test reports and current standards.
Manufacturers lack a report register managed by standard version, and transition milestones are unclear.
Performance indicators in the dedicated association standard are not built into factory inspection or supplier management.

Solution

Build a four-way register covering standard version, report, nameplate labelling and key components.
Use the current standard list in Table 1 as the single baseline and remove all old standard numbers.
Use T/CHEAA 0031—2024 as the benchmark for performance and hygiene and build it into type testing.

Execution

Step 1: within 30 days, replace standard numbers on nameplates, packaging, manuals and detail pages of all SKUs on sale.
Step 2: within 60 days, schedule testing for safety, EMC, battery and harmonic current.
Step 3: within 90 days, collect new-edition reports or declarations of conformity from key-component suppliers.
Step 4: establish a quarterly register review; any standard announcement change triggers reassessment.

Acceptance model

Metric 1: 100% consistency between nameplate/manual standard numbers and the current list.
Metric 2: safety, EMC, battery and harmonic reports all on current editions, 100% coverage.
Metric 3: 100% pass rate on in-house checks of association-standard performance indicators — pressure ≤78 kPa, heat ≤43 °C, noise ≤55 dB(A), life ≥250 h.
Metric 4: 100% completeness of new-edition documents from key-component suppliers.
Metric 5: zero non-conformities in platform sampling and supervision sampling.

Comments (10)

Chen, Product Manager: Finally a standard list I can send straight to suppliers. Tables 1 and 3 are already in our supplier group.
Lin, Quality Engineer: One reminder: don't gamble on partial re-testing of safety reports. Temperature rise and flame retardancy have too many variables; full testing is the least painful route.
Zhou, Regulatory Specialist: The section on the change from GB to GB/T is spot on. Many people assume a recommended standard can be skipped, but platform sampling still enforces the new edition.
Wang, Supply Chain: Battery reports switched in January 2024. We were burned last year when a supplier kept sending 2014-edition reports; they went straight back for redoing.
Zhao, E-commerce Operations: Our detail page still shows the 2005 edition number. Fixing it right after reading this, thanks for the reminder.
Wu, Structural Engineer: The 43 °C heat ceiling has to be designed in from the start — heating film bonding and heat dissipation paths both matter.
He, Test Engineer: Suggest adding the specific measurement points for the 15-minute continuous operation condition; we want our internal pre-test to align.
Liu, Factory Director: We already sample factory inspection to GB/T 2828.1, but the items were not mapped to the association standard. We will close that gap.
Zheng, Brand Owner: "No CCC does not mean no constraints" should be pinned above every e-commerce operator's desk.
Sun, Industry Observer: Once the association standard quantified pressure, temperature and noise, this category finally gained a comparable technical language. Good for the long run.

Massager and Beauty Device Basics

Why should airbag pressure in an eye massager have an upper limit?
The eyeball and the tissues around the eyes are sensitive to pressure.
When pressure is too high, force passes through the eyelid to the surface of the eye, which in the short term can cause a feeling of pressure or blurred vision, and with repeated exposure over time can easily cause discomfort.
T/CHEAA 0031—2024 caps airbag pressure at 78 kPa during operation for exactly this reason.
When choosing a device, look beyond the pressure rating: check for automatic shutdown, low-battery alerts and a heat temperature ceiling.
In use, keep each session under 15 minutes, avoid leaving the heat mode on continuously for long periods, and remove contact lenses first.
If noticeable swelling, pain or abnormal vision occurs, stop using the device immediately and consult a professional.

View eye massager product details →  

Frequently Asked Questions (100 · first 50 shown)

  1. What are the current standards for eye massager complete machines?Safety: GB/T 4706.1—2024 and GB/T 4706.10—2024.
    Dedicated: T/CHEAA 0031—2024.
    Supporting: GB 4343.1—2024, GB/T 4343.2—2020, GB 17625.1—2022 and GB 31241—2022.
  2. When does GB/T 4706.1—2024 take effect?It takes effect on 1 August 2026 and fully replaces GB 4706.1—2005.
  3. Which older standard does GB/T 4706.10—2024 replace?It replaces GB 4706.10—2008 and takes effect on 1 August 2026.
  4. What is the effective date of GB 4343.1—2024?It takes effect on 1 June 2026 and replaces GB 4343.1—2018.
  5. When does GB 31241—2022 take effect?It took effect on 1 January 2024 and replaces GB 31241—2014.
  6. Does an eye massager need CCC certification?Generally no.
    The mandatory product certification catalogue does not include massage appliances.
    Supervision sampling and platform review still follow current standards.
  7. What is T/CHEAA 0031—2024?It is the China Household Electrical Appliances Association standard "Household and similar eye massagers", published and effective on 2 April 2024.
  8. Does T/CHEAA 0031—2024 replace an older standard?No.
    It is a newly created standard with no predecessor.
  9. Can old safety reports still be used?After 1 August 2026 they can no longer serve as evidence of compliance with current standards and must be re-tested to the new editions.
  10. How should the standard be marked on the nameplate?Standards: GB/T 4706.1—2024, GB/T 4706.10—2024, T/CHEAA 0031—2024.
    Models with built-in lithium batteries should also mark GB 31241—2022.
  11. Is GB/T 4706.1—2024 mandatory or recommended?It is a recommended national standard.
    It is cited in local sampling rules and e-commerce platform quality rules, so it is enforced as mandatory in practice.
  12. Can recommended standards be ignored?Not advisable.
    Once cited in supervision sampling rules, platform rules or contracts, they become binding in practice.
  13. What is the maximum airbag pressure for eye massagers?Airbag pressure during operation shall not exceed 78 kPa.
  14. What is the maximum heat temperature?The surface temperature of body-contact parts shall not exceed 43 °C.
  15. What is the noise limit?Sound power level not exceeding 55 dB(A-weighted), excluding music playback.
  16. What is the maximum massage timer duration?The time from power-on to automatic shutdown shall not exceed 15 min, with a timing error not exceeding ±2%.
  17. What is the required operating life?Not less than 250 h; the appliance shall still operate normally after the life test.
  18. What is the required button life?Mechanical buttons not less than 10,000 cycles, with normal operation after the test.
  19. What is the required charging port life?Not less than 1,000 cycles, with good contact and normal charging after the test.
  20. What is the antibacterial rate requirement?Components claimed as antibacterial shall have an antibacterial rate of not less than 90%.
  21. What is the anti-mold grade requirement?Components claimed as anti-mold shall have an anti-mold grade of not lower than grade 1.
  22. What is the perspiration color fastness requirement?Textile parts shall be not lower than grade 4.
  23. Which category applies to direct skin-contact fabrics?The direct skin-contact (Category B) requirements of GB 18401.
  24. What is the coating adhesion requirement?Not lower than grade 2 of GB/T 9286.
  25. Can the device operate while charging?No.
    The association standard requires that the appliance shall not start or operate during charging.
  26. Which immunity test does the association standard cover?Only electrostatic discharge.
  27. Is ESD testing alone sufficient?At association-standard level, yes.
    For EU export or customer requirements, the full immunity suite should be tested.
  28. Has the harmonic current standard been updated?Yes. GB 17625.1—2022 took effect on 1 July 2024, replacing the 2012 edition.
  29. Is GB/T 4343.2—2020 still valid?It is currently still in force.
    It will switch over when GB/T 4343.2—2026 takes effect.
  30. When does GB/T 4343.2—2026 take effect?It has been published; the specific effective date follows the national standard announcement.
  31. Must battery reports use the 2022 edition?Yes.
    From 1 January 2024, battery reports must be issued to GB 31241—2022.
  32. Can CB reports be converted directly for EU export?No direct conversion is possible.
    Identical adoption can be used for technical comparison to reduce duplicate testing, but sales in China still require reports from an accredited body.
  33. Do derived models need re-testing?Appearance or colour changes only can be listed in a report change page.
    Changes to structure, key components or safety parameters require re-submission.
  34. What kind of institution should issue test reports?It is recommended to use a body holding CMA and CNAS accreditation.
  35. What happens if old standard numbers remain on packaging?It will be judged as labelling inconsistent with current standards, creating supervision sampling and platform review risk.
  36. Do these standards apply to electrical-pulse eye massagers?No.
    EMS and TENS devices follow a different standards route and require separate assessment.
  37. What is the risk of claiming to treat myopia?Such claims fall within medical-device claims and require the medical-device registration or filing route.
  38. What extra steps are required for Bluetooth?Radio transmission equipment type approval must be obtained, and the module model and approval code must be stated in the manual or on an information page.
  39. Where should the type approval code be written?In the instruction manual or on a separate information page.
  40. What is the difference between factory inspection and type testing?Factory inspection covers appearance, general function, marking and other items that can be judged quickly.
    Type testing covers all requirements of Chapter 4.
  41. What sampling standard is used for factory inspection?GB/T 2828.1.
  42. When is type testing required?At product type approval, on major changes to structure or key components, on resumption of production after a stoppage, and during periodic sampling.
  43. Is full re-testing required after the transition?Where differences are unclear, full re-testing is recommended as it is safer than testing selected items.
  44. Which operating conditions matter most for temperature-rise testing?Heat and charging operating simultaneously, and 15 minutes of continuous operation.
  45. Which parts are subject to flame-retardancy testing?Non-metallic materials such as housings and eye masks.
  46. What does the transition require from the supply chain?Battery, heating film, air pump and mask suppliers must provide new-edition reports or declarations of conformity in step.
  47. Has the hazardous substances standard been updated?No. GB/T 26572—2011 remains valid.
  48. Is GB 18401—2010 still valid?Yes, it was not revised in this round.
  49. Does the instruction manual need to state the standards?Marking the standards is voluntary, but platform review, tender procurement and supervision sampling commonly require it, so it is advisable to list them in full.
  50. Which standards do platform spot checks rely on?The currently valid national standards and the dedicated association standard, i.e. the list in Table 1 of this document.

↑

Name:
Message:
Verification code:
Submit
Comment
Location:
Eye Massager Complete Machine Standards Guide: Current vs. Superseded Standards, Key Technical Indicators and Compliance Path
Phone
+8613360508085
Online
service online
在线客服系统