Current vs. superseded standards, key technical indicators and compliance implementation path · Version V1.1 · Compiled 17 November 2026
This document defines the current basis for standards compliance, factory inspection, third-party testing and platform compliance for eye massagers used in households and similar environments.
It can be cited directly by product definition, quality acceptance, supplier management and e-commerce onboarding teams.
It applies to complete machines that act on the eye area through airbag compression, mechanical pressing or heat compress.
This includes models powered by built-in lithium batteries, models powered by external adapters, and models with auxiliary functions such as Bluetooth music or voice prompts.
It does not apply to medical-use products or shared commercial products, nor to eye massagers based on electrical pulse principles (EMS, TENS).
The standards route for those products differs; see Section 6.3.
Standard status in this document was verified as of 17 November 2026.
The sources are the standard status and effective dates published on the National Standards Information Public Service Platform of the Standardization Administration of China, the text of T/CHEAA 0031—2024 issued by the China Household Electrical Appliances Association, and the mandatory product certification implementation rules of the CNCA.
Where standard status, effective dates or supersession relationships change, the official platform prevails.
From 1 August 2026, GB/T 4706.1—2024 and GB/T 4706.10—2024 take effect.
They fully replace GB 4706.1—2005 and GB 4706.10—2008 respectively.
GB 4343.1—2024 takes effect on 1 June 2026, replacing GB 4343.1—2018.
This means the "standards" entry on nameplates, in instruction manuals and in test reports must be updated to the new numbers.
Continuing to mark the 2005 or 2008 editions will be judged as labelling inconsistent with current standards.
The current basis for the complete machine can be summarised as two safety national standards, one dedicated association standard and four supporting standards.
The safety standards are GB/T 4706.1—2024 and GB/T 4706.10—2024.
The dedicated performance and hygiene standard is T/CHEAA 0031—2024.
The supporting standards are GB 4343.1—2024, GB/T 4343.2—2020, GB 17625.1—2022 and GB 31241—2022.
Note that GB/T 4706.1—2024 and GB/T 4706.10—2024 are recommended national standards.
However, both are cited in local massage-appliance quality supervision sampling rules and in e-commerce platform quality rules, so they are enforced as mandatory in practice.
The "GB/T" prefix must not be taken as a reason to lower requirements.
Table 1 — Current standards for the eye massager complete machine
| No. | Category | Standard No. | Title | Effective date | Status |
|---|---|---|---|---|---|
| 1 | Safety (general) | GB/T 4706.1—2024 | Household and similar electrical appliances — Safety — Part 1: General requirements | 2026-08-01 | Recommended |
| 2 | Safety (particular) | GB/T 4706.10—2024 | Household and similar electrical appliances — Safety — Part 10: Particular requirements for massage appliances | 2026-08-01 | Recommended |
| 3 | Dedicated product | T/CHEAA 0031—2024 | Household and similar eye massagers | 2024-04-02 | Association standard |
| 4 | EMC emission | GB 4343.1—2024 | Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 1: Emission | 2026-06-01 | Mandatory |
| 5 | EMC immunity | GB/T 4343.2—2020 | Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity | 2021-07-01 | Recommended |
| 6 | Harmonic current | GB 17625.1—2022 | Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase) | 2024-07-01 | Mandatory |
| 7 | Lithium battery | GB 31241—2022 | Safety technical specification for lithium-ion cells and batteries used in portable electronic products | 2024-01-01 | Mandatory |
Source: National Standards Information Public Service Platform (std.samr.gov.cn).
Status verified as of 17 November 2026.
GB/T 4343.2—2026 has been published and will fully replace the 2020 edition; it should be adopted once it takes effect.
The safety and supporting standards relevant to eye massagers were mostly issued between 2005 and 2018, and all previous editions have now been withdrawn.
There are two reasons to keep a list of the old editions.
First, to check whether nameplates, manuals, tender documents and purchase contracts still cite withdrawn standard numbers.
Second, to define the comparison baseline for transition re-testing and clarify which items must be repeated.
Previously there was no dedicated product standard for eye massagers.
Manufacturers generally wrote their own enterprise standards, or referred to GB 4706.10 and QB/T 4412 "Hand-held electric massagers".
T/CHEAA 0031—2024 is a newly created standard rather than a replacement of an older one, so it is not listed in the table below.
Table 2 — Withdrawn or superseded standards
| No. | Standard No. | Title | Status | Withdrawal date | Replaced by |
|---|---|---|---|---|---|
| 1 | GB 4706.1—2005 | Household and similar electrical appliances — Safety — Part 1: General requirements | Mandatory | 2026-08-01 | GB/T 4706.1—2024 |
| 2 | GB 4706.10—2008 | Household and similar electrical appliances — Safety — Part 10: Particular requirements for massage appliances | Mandatory | 2026-08-01 | GB/T 4706.10—2024 |
| 3 | GB 4343.1—2018 | Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 1: Emission | Mandatory | 2026-06-01 | GB 4343.1—2024 |
| 4 | GB 17625.1—2012 | Electromagnetic compatibility — Limits — Part 1: Limits for harmonic current emissions (equipment input current ≤16 A per phase) | Mandatory | 2024-07-01 | GB 17625.1—2022 |
| 5 | GB 31241—2014 | Safety technical specification for lithium-ion cells and batteries used in portable electronic products | Mandatory | 2024-01-01 | GB 31241—2022 |
| 6 | GB/T 4343.2—2020 | Electromagnetic compatibility requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity | Recommended | Date GB/T 4343.2—2026 takes effect | GB/T 4343.2—2026 |
Source: standard status and supersession relationships on the National Standards Information Public Service Platform.
"Withdrawal date" is the date on which the superseded standard ceases to apply.
It is recommended to mark the "Standards" entry on the nameplate in full as follows.
Standards: GB/T 4706.1—2024, GB/T 4706.10—2024, T/CHEAA 0031—2024.
Models with built-in lithium batteries should also mark GB 31241—2022.
Chapter 7 of GB/T 4706.1—2024 requires appliances to state the manufacturer or responsible party name, model or serial number, rated voltage, rated input power or current and other parameters.
Marking the standards is voluntary, but e-commerce platform review, tender procurement and quality supervision sampling commonly require it, so it is advisable to list it in full.
Products with Bluetooth or other wireless modules should also state the module model and the radio transmission equipment type approval code in the manual or on a separate information page.
The table below compares old standard, new standard, switch-over date and main changes.
It can be used directly for transition reviews, report registers and supplier communication.
The "main changes" column lists only verifiable facts and official interpretations.
Detailed clause differences should still be compared line by line against the standard texts; this table alone should not be used to decide whether a specific test must be repeated.
Table 3 — Old-versus-new comparison for eye massagers
| Category | Old standard (withdrawn) | New standard (current) | Switch-over date | Main changes and impact |
|---|---|---|---|---|
| Safety (general) | GB 4706.1—2005 | GB/T 4706.1—2024 | 2026-08-01 | Status changed from mandatory GB to recommended GB/T. Identical adoption of IEC 60335-1:2016. Scope, temperature-rise limits and material flame-retardancy requirements are raised; legacy report data cannot be reused. |
| Safety (particular) | GB 4706.10—2008 | GB/T 4706.10—2024 | 2026-08-01 | Same status change. Identical adoption of IEC 60335-2-32:2019, aligned with the current international edition. Classification, test conditions and pass criteria for massage appliances are updated. |
| EMC emission | GB 4343.1—2018 | GB 4343.1—2024 | 2026-06-01 | From 2025-04-20 to 2026-05-31 either edition may be chosen. From 2026-06-01 only new-edition certificates are issued. Emission limits and measurement methods follow the new edition. |
| EMC immunity | GB/T 4343.2—2020 | GB/T 4343.2—2026 | Date the 2026 edition takes effect | Modified adoption of CISPR 14-2:2020. The 2020 edition remains valid until the new edition takes effect, after which immunity is assessed to the new edition. |
| Harmonic current | GB 17625.1—2012 | GB 17625.1—2022 | 2024-07-01 | Limits and test conditions follow the new edition. CCC certification and quality supervision sampling switch over in step. |
| Lithium battery | GB 31241—2014 | GB 31241—2022 | 2024-01-01 | Covers electrical safety, mechanical safety, environmental testing and protection circuits. Battery reports must be issued to the 2022 edition. |
| Dedicated product | No dedicated standard (enterprise standards or reference to QB/T 4412) | T/CHEAA 0031—2024 | 2024-04-02 | Establishes complete-machine indicators for airbag pressure, heat temperature, noise and life for the first time. A new standard with no predecessor. |
| Hazardous substances | GB/T 26572—2011 | Remains valid, no replacement | — | Not revised in this round; assessed together with RoHS compliance. |
| Textile safety | GB 18401—2010 | Remains valid, no replacement | — | Eye masks, straps and other skin-contact parts are assessed as Category B. |
Sources: standard status and supersession relationships on the National Standards Information Public Service Platform; CNCA and China Quality Certification Centre transition notices; July 2026 standard interpretation by the Beijing Municipal Administration for Market Regulation.
The revision of the safety standards involves two layers of change.
One is the status of the standard and the other is its technical content; they mean different things for manufacturers.
On status: GB 4706.1—2005 and GB 4706.10—2008 were mandatory national standards.
The new editions are recommended national standards, numbered GB/T 4706.1—2024 and GB/T 4706.10—2024.
The status change does not mean requirements are relaxed.
Both standards are cited in local massage-appliance quality supervision sampling rules and e-commerce platform quality rules, so sampling and platform review still follow the new editions.
On technical content: according to the standard interpretation published by the Beijing Municipal Administration for Market Regulation in July 2026, the new editions raise requirements in scope, temperature-rise limits, material flame-retardancy testing and other dimensions.
Three points affect eye massagers most directly.
The boundary conditions and limits of the temperature-rise test.
The flame-retardancy class of non-metallic materials such as housings and eye masks.
The judgement criteria for construction and marking checks.
Temperature-rise and flame-retardancy data in legacy reports cannot be cited directly and must be re-tested to the new editions.
On international alignment: the two new standards identically adopt IEC 60335-1:2016 and IEC 60335-2-32:2019 respectively.
Models that already hold CB reports or CE-LVD reports can use them for technical comparison to reduce duplicate testing.
However, identical adoption does not mean reports can be converted directly; sales in China still require reports issued by an accredited body.
GB 4343.1—2024 replaces GB 4343.1—2018 and takes effect on 1 June 2026.
The transition arrangement published by the China Quality Certification Centre is as follows: from 20 April 2025 to 31 May 2026, manufacturers may choose to certify to either the new or the old edition.
From 1 June 2026, certification must follow the new edition and new-edition certificates are issued; old-edition certificates are no longer issued.
Although eye massagers are not in the mandatory product certification catalogue, EMC reports and platform sampling also follow the new edition.
On immunity: GB/T 4343.2—2020 is currently still in force.
GB/T 4343.2—2026 has been published and will fully replace the 2020 edition, with modified adoption of CISPR 14-2:2020, and must be adopted once it takes effect.
T/CHEAA 0031—2024 selects only electrostatic discharge, which is the minimum requirement of a product standard.
Other immunity items cannot be considered exempt on that basis.
On harmonic current: GB 17625.1—2022 took effect on 1 July 2024, replacing the 2012 edition.
Models powered by an external adapter, or operating while charging, should be tested to the new edition.
Battery is the earliest item to take effect in this transition round.
GB 31241—2022 took effect on 1 January 2024, replacing GB 31241—2014, and covers electrical safety, mechanical safety, environmental testing and protection circuits.
Built-in batteries and charging-case batteries in eye massagers are assessed to this standard, and reports must be issued to the 2022 edition.
Models holding only 2014-edition reports should be re-tested as soon as possible.
Hazardous substances and textile safety were not revised in this round.
GB/T 26572—2011 and GB 18401—2010 remain valid, covering RoHS limits and direct skin-contact (Category B) requirements respectively.
No new certification is needed at transition, but the edition numbers cited in reports and declarations should match the current editions to avoid referencing withdrawn versions.
The practical impact of the transition centres on four areas: labelling, reports, design and the supply chain.
The recommended sequence is as follows.
T/CHEAA 0031—2024 was proposed by Shenzhen Breo Technology Co., Ltd. and is administered by the China Household Electrical Appliances Association.
It was published and took effect on 2 April 2024 and is the only dedicated complete-machine standard for this category.
The national standards system addresses the "safety floor" and does not specify performance such as airbag pressure, heat temperature, noise or life.
The association standard fills that gap and is the technical basis most often cited in platform quality checks, procurement acceptance and consumer complaint handling.
The standard applies to eye massagers used in households and similar places.
It explicitly does not apply to medical uses, commercial uses or eye massagers based on electrical pulse principles.
Under continuous no-load operation, continuous disturbance limits and discontinuous disturbance limits shall comply with GB 4343.1—2024.
Immunity is assessed against the electrostatic discharge requirement of GB/T 4343.2.
The association standard selects only ESD, which does not exempt the complete machine from other immunity items.
For EU export or customer requirements, the full immunity suite should be tested.
Table 4 — Key performance indicators in T/CHEAA 0031—2024
| Item | Requirement | Key test conditions |
|---|---|---|
| Massage timer | With a full charge, the time from power-on to automatic shutdown shall match the instruction manual and shall not exceed 15 min, with a timing error not exceeding ±2% | Timed from start to automatic shutdown |
| Automatic shutdown | The appliance shall shut down automatically when the massage time is reached | Assessed together with the massage timer |
| Heat temperature | Shall match the rated specification in the manual, and the surface temperature of body-contact parts shall not exceed 43 °C | Ambient 23±2 °C, without significant airflow or heat radiation |
| Operating noise | Sound power level not exceeding 55 dB(A-weighted), excluding music playback | Full charge, no load, all functions enabled |
| Low-battery alert | A low-battery alert shall be provided, by sound, light or vibration | Observed at the low-battery state |
| Operating life | Not less than 250 h; the appliance shall still operate normally after the life test | Continuous or cyclic operation under specified conditions |
| Button life | Mechanical buttons not less than 10,000 cycles; normal operation after the test | Cyclic pressing at normal use frequency |
| Charging port life | Not less than 1,000 cycles; good contact and normal charging after the test | Standard insertion/removal cycles |
| Drop (bare unit) | The appliance shall operate normally after the drop | Relevant methods of GB/T 2423.7 |
| Drop (packaged) | No abnormality in appearance, structure or function | Drop with full packaging |
| Appearance and coating | No scratches, scuffs or cracks on the surface. Coating adhesion not lower than grade 2 of GB/T 9286 | 40 W fluorescent light, 45° angle, 30 cm viewing distance |
Source: T/CHEAA 0031—2024 "Household and similar eye massagers", clauses 4.3 and 4.7 and Chapter 5 test methods.
The standard divides inspection into factory inspection and type testing.
Factory inspection uses GB/T 2828.1 sampling and covers appearance, general function, marking and other items that can be judged quickly.
Type testing covers all requirements of Chapter 4 and is performed at product type approval, on major changes to structure or key components, on resumption of production after a stoppage, and during periodic sampling.
In-house inspection plans should correspond item by item to the association standard; factory inspection cannot replace type testing.
The withdrawal of the old editions does not happen on a single day.
Managing reports and labelling against the milestones below avoids the mismatch of "the new standard is in force but the report is still the old edition".
Table 5 — Old-to-new switch-over milestones
| Date | Event | What manufacturers must do |
|---|---|---|
| 2024-01-01 | GB 31241—2022 takes effect | Battery reports issued to the 2022 edition; 2014-edition reports cease to be used |
| 2024-04-02 | T/CHEAA 0031—2024 takes effect | Benchmark complete-machine performance and hygiene indicators against it; usable as a higher-level reference for enterprise standards |
| 2024-07-01 | GB 17625.1—2022 takes effect | Harmonic current tested to the new edition |
| 2025-04-20 to 2026-05-31 | GB 4343.1 transition window | Either edition may be chosen; testing directly to the new edition avoids a second transition |
| 2026-06-01 | GB 4343.1—2024 becomes mandatory | Only new-edition certificates are issued; legacy EMC reports become invalid |
| 2026-08-01 | GB/T 4706.1 and GB/T 4706.10—2024 take effect | Old safety editions are withdrawn; safety reports must be re-tested |
| Date GB/T 4343.2—2026 takes effect | Immunity standard transition | According to the national standard announcement; assessed to the new edition thereafter |
Note: the dates above are standard effective dates or policy deadlines; the national standard announcement and certification body notices prevail.
Building a report register by standard version, with re-testing triggered by any version change, is more reliable than replacing reports on a fixed cycle.
For this product specifically, the suggestions are as follows.
The current "Implementation Rules for Mandatory Product Certification — Household and Similar Electrical Appliances" (CNCA-C07-01:2024) covers household refrigerators, electric fans, air conditioners, household electric washing machines, electric water heaters, room heaters, vacuum cleaners, skin and hair care appliances, electric irons, induction cookers, electric ovens, electric food processing appliances, microwave ovens and others; massage appliances are not included.
Eye massagers therefore generally do not require CCC certification.
But "no CCC" does not mean "no standard constraints".
Product quality supervision sampling, platform onboarding review and tender qualification checks all follow the standards in Chapter 2, and the absence of a conformity report is itself a compliance risk.
It is recommended to obtain in one go a complete-machine report covering safety, EMC, battery and hazardous substances.
It should be issued by a body holding CMA and CNAS accreditation, and the report should show the full standard numbers with edition years.
Platforms generally require recent reports from accredited bodies; the specific validity period and items depend on each platform's onboarding rules.
Derived models of the same type (appearance or colour changes only) can be listed in a report change page.
Changes to structure, key components or safety parameters require re-submission.
Table 6 — Boundary compliance risks for eye massagers
| Risk type | Trigger | Correct handling |
|---|---|---|
| Medical device | Claims of treating myopia, dry eye, cataract or restoring vision, or design based on medical-device principles | Follow the medical-device registration or filing route; household-appliance testing alone is insufficient |
| Radio transmission | Built-in Bluetooth, Wi-Fi or other wireless modules without radio transmission equipment type approval | Obtain type approval and state the module model and approval code in the manual or on an information page |
| Electrical pulse | EMS, TENS or other electrical pulse methods applied around the eyes | The standards route differs; assess against the applicable standards and regulations rather than this list |
It is recommended to start testing at least 90 days before the transition effective dates.
Full safety re-testing and EMC re-testing can be scheduled in parallel.
Battery and key-component reports should be confirmed first, so that supply-chain documentation delays do not hold up complete-machine certification.
The core value of this document is that it translates "standard numbers" back into "executable compliance actions".
The eye-massager category long lacked a dedicated national standard: safety relied on general household-appliance standards, and performance relied on each manufacturer's own enterprise standard.
The introduction of T/CHEAA 0031—2024 writes airbag pressure, heat temperature, noise, life and hygiene — indicators that directly affect user experience — into a formal text for the first time.
This shifts competition from "can it pass safety" to "can performance indicators be quantitatively verified".
Looking at the transition schedule, this round of adjustment does not complete on a single day.
The battery standard came first in January 2024, harmonic current followed in July 2024, EMC emission switches in June 2026, the two safety national standards land in August 2026, and the immunity standard is still pending.
The risk most easily overlooked in such staggered transitions is a mixed state where some reports have been updated and others have not.
Manufacturers who replace reports on a fixed cycle can easily end up with a report that no longer matches the standard at some point in time.
Another point worth noting is the change in standard status.
The two safety national standards move from mandatory GB to recommended GB/T, which looks like a relaxation on the surface.
But supervision sampling rules and e-commerce platform quality rules still follow the new editions, so the practical binding force has not decreased.
The lesson for manufacturers is that compliance judgement cannot rely on the prefix alone; it depends on the referencing context.
In summary, the rollout priorities in this document can be reduced to three sentences.
Update the nameplate first, then fill in the reports.
Where differences are unclear, run the full suite.
Transition the supply chain in step.
Put these three tasks into the project plan against the milestones and the transition risk is largely under control.
Staggered old-to-new transitions create mismatches between nameplate labelling, test reports and current standards.
Manufacturers lack a report register managed by standard version, and transition milestones are unclear.
Performance indicators in the dedicated association standard are not built into factory inspection or supplier management.
Build a four-way register covering standard version, report, nameplate labelling and key components.
Use the current standard list in Table 1 as the single baseline and remove all old standard numbers.
Use T/CHEAA 0031—2024 as the benchmark for performance and hygiene and build it into type testing.
Step 1: within 30 days, replace standard numbers on nameplates, packaging, manuals and detail pages of all SKUs on sale.
Step 2: within 60 days, schedule testing for safety, EMC, battery and harmonic current.
Step 3: within 90 days, collect new-edition reports or declarations of conformity from key-component suppliers.
Step 4: establish a quarterly register review; any standard announcement change triggers reassessment.
Metric 1: 100% consistency between nameplate/manual standard numbers and the current list.
Metric 2: safety, EMC, battery and harmonic reports all on current editions, 100% coverage.
Metric 3: 100% pass rate on in-house checks of association-standard performance indicators — pressure ≤78 kPa, heat ≤43 °C, noise ≤55 dB(A), life ≥250 h.
Metric 4: 100% completeness of new-edition documents from key-component suppliers.
Metric 5: zero non-conformities in platform sampling and supervision sampling.
Why should airbag pressure in an eye massager have an upper limit?
The eyeball and the tissues around the eyes are sensitive to pressure.
When pressure is too high, force passes through the eyelid to the surface of the eye, which in the short term can cause a feeling of pressure or blurred vision, and with repeated exposure over time can easily cause discomfort.
T/CHEAA 0031—2024 caps airbag pressure at 78 kPa during operation for exactly this reason.
When choosing a device, look beyond the pressure rating: check for automatic shutdown, low-battery alerts and a heat temperature ceiling.
In use, keep each session under 15 minutes, avoid leaving the heat mode on continuously for long periods, and remove contact lenses first.
If noticeable swelling, pain or abnormal vision occurs, stop using the device immediately and consult a professional.